Figure out what kind of no-start you have
A dryer that will not start can behave in several different ways, and each one points somewhere different. Before checking anything, note exactly what happens when you press Start.
- Completely dead. No lights, no display, no sound. Think power supply, outlet, breaker or a main control fault.
- Display on, nothing happens. The panel lights up but the drum never turns. Common causes are the door switch, a control lock, a thermal fuse or the start switch.
- Hums but does not turn. The motor is trying to run but the drum is not moving. This often points to a broken belt, a seized drum roller or a motor problem.
- Starts, then stops after a few seconds. On many models this happens when the belt has snapped or a motor or safety device cuts power.
Write down any code on the display, too. It can save a lot of guesswork.
Check the power supply
Electric dryers in the US typically run on a 240-volt circuit with a two-pole breaker. If only one half of that breaker trips, some models will light up but not run, or run but not heat. Turning the breaker fully off and then back on resets both sides.
- Find the dryer breaker in your panel and switch it firmly off, then on.
- Make sure the plug is fully seated in the wall outlet. Dryers are heavy, and pushing them back can partly pull the plug out.
- Gas dryers also need electricity. They plug into a standard 120-volt outlet for the motor, controls and igniter, so check that outlet and its breaker as well.
- Look at the power cord. If it is scorched, melted or cracked, do not use the dryer.
If a breaker trips again right away, leave it off. That is a sign of a short or a failing component, and the wiring needs a professional.
Door switch, control lock and settings
Every dryer has a door switch that stops it from running with the door open. If the switch is worn or its actuator is broken, the dryer thinks the door is open even when it is closed.
- Close the door firmly. Listen for the click of the switch. Lint or a bent latch can keep it from engaging.
- Check the drum light. On many models the drum light turns off when the door closes. If it stays on with the door shut, the switch may not be making contact.
- Turn off control lock. Many dryers have a control or child lock that disables the buttons. Look for a lock icon and the button you hold for a few seconds to release it.
- Press Start long enough. Some dryers need the Start button held for a second or two rather than tapped.
- Check delay start. A delay set by accident will make the dryer seem dead until the timer runs down.
The thermal fuse and why it blows
Many dryers have a thermal fuse, a small one-time safety device mounted on the blower housing or exhaust duct. When the air leaving the drum gets too hot, the fuse opens and cuts power. On many models that means the dryer will not start at all, while on others it runs but will not heat.
A thermal fuse does not blow by itself. In most cases it opens because hot, moist air could not leave the dryer fast enough, usually from a lint-packed exhaust vent, a crushed transition hose behind the dryer, or a clogged lint screen. A failing heating element or cycling thermostat can also cause overheating.
That is why simply swapping the fuse is not a real repair. If the airflow problem stays, the new fuse will blow again, and the dryer is running hotter than it should. A technician will replace the fuse, test the heat circuit and check airflow at the same time.
Venting and airflow
Restricted airflow is the hidden cause behind many dryer failures, including no-starts, long drying times and overheating. You can do a few safe checks yourself.
- Clean the lint screen before every load, and wash it with warm soapy water now and then if dryer sheets leave a film on it.
- With the dryer off, look behind it. The flexible transition duct should not be crushed, kinked or full of lint.
- Go outside while the dryer runs and check the vent hood. You should feel a strong flow of warm air, and the flap should open.
If the vent run is long, has lint buildup or the outside flap barely moves, contact a dryer vent cleaning service. Mr. Fixer repairs the dryer itself and checks airflow during diagnosis, but we do not clean, replace or reroute dryer vents. Our guide on a dryer that takes too long to dry explains more about airflow.
Belt, motor and control problems
When power, the door and the fuse all check out, the fault is usually deeper inside the cabinet.
- Broken drive belt. On many models, a belt switch or the motor's own design stops the dryer when the belt breaks. If the drum spins freely by hand with almost no resistance, the belt has likely snapped.
- Drive motor. A motor that hums without turning, or trips its internal overload and goes quiet, may need replacing.
- Start switch or timer. On dryers with a dial, a worn start switch or timer contacts can stop the signal from reaching the motor.
- Main control board. On electronic models, a failed board can leave the display working but the dryer unable to start.
These repairs involve live wiring, sharp sheet metal and heavy parts, so they are best left to a technician. For noise-related problems, see our guide to a dryer making noise.
When to call for dryer repair
Call a technician if the dryer stays dead after you reset the breaker and checked the outlet, if the display lights but the drum never turns, if it hums without spinning, or if a breaker keeps tripping. Stop using it right away if you smell burning or see scorch marks.
Mr. Fixer provides dryer repair across Metro Atlanta for gas and electric models from Whirlpool, Samsung, LG, Maytag and other brands. If your LG shows a code, our LG dryer error code guide may help. The $80 diagnostic is credited toward the repair, and you get a written estimate before work starts. Call (678) 866-3669 or book online.
Need it fixed?
Our technicians handle dryer repair across Metro Atlanta, usually the same day. Diagnostic from $80, credited toward your repair.
Call (678) 866-3669FAQs
Why does my dryer have power but will not start?
When the display lights up but the drum does not turn, the most common causes are a door switch that is not engaging, an active control lock, a blown thermal fuse, a broken belt or a faulty start switch or control board.
Is there a reset button on a dryer?
Most home dryers do not have a single reset button. Switching the breaker off for a minute and back on resets the electronic controls on many models. A blown thermal fuse cannot be reset and must be replaced.
Can a clogged dryer vent stop a dryer from starting?
Yes, indirectly. A clogged vent makes the dryer overheat, and on many models that blows the thermal fuse, which stops the dryer from starting or heating. Have the vent cleaned by a vent cleaning service as well as repairing the dryer.
Does a gas dryer need electricity?
Yes. Gas dryers use a standard 120-volt outlet to power the motor, controls and igniter. If that outlet or its breaker has no power, a gas dryer will not start.
More repair guides

Dryer Not Heating? Causes, Safe Checks and Fixes
A dryer that runs but does not heat usually has a blown thermal fuse, a failed heating element (electric) or igniter (gas), a bad thermostat, or a tri…
Read the guide →
LG Dryer Not Heating: Causes and What to Check
An LG dryer that tumbles but stays cold usually has a blown thermal fuse, a failed heating element or igniter, a bad thermistor, or a tripped thermal …
Read the guide →
Dryer Takes Too Long to Dry? Causes and Fixes
A dryer that needs two or three cycles to finish a load is usually held back by restricted airflow: a clogged lint screen, a crushed or lint-packed ve…
Read the guide →